Product Keywords: Stable transient fluorescence light, steady state transient fluorescence spectrum, TRPL, TRES, fluorescence lifetime, electrotransient, TREL, fluorescence spectrum, transient fluorescence, fluorescence quantum yield, PLQY, variable temperature fluorescence, time-resolved photofluorescence spectrum, excitation spectrum, emission spectrum, synchronization spectrum, transient phosphorescence, phosphorescence lifetime, fluorescence phosphorescence decay lifetime, ultrafast spectrum, kinetic scanning , multi-emission spectrum scanning, multi-synchronous scanning
▌ Product introduction
Photoelectric integrated time-resolved spectrometer HiLight is the industry's first photoelectric integrated time-resolved spectrometer (also known as photoinduced/electrostabilized transient/time-resolved fluorescence spectrometer TRPL) independently developed by Oriental Spectra Technology.
The equipment has photoinduced and electrofluorescence spectrum modules. Full stable, transient test analysis of all types of photoinduced (fluorescent, phosphorescent, delayed fluorescence, etc.) and electroluminescent samples can be performed, and weak luminescent signals can be accurately measured in the broad time domain range from 200 nm to 5500 nm, wide wavelength, 2.5 ns to 1200 s.
Based on the unique advantages of photoelectric integration, HiLight can be used for the research of materials and devices at the same time, which greatly expands the application range of traditional fluorescence spectrometer. Based on the modular design concept, HiLight can provide flexible configuration solutions to adapt to diverse test needs, and can be widely used in materials science, analytical science, biomedicine, food science, petrochemical, geology, archaeology, forensic science and other fields.
▌ Product characteristics
□ Modular design, optional configuration is rich and flexible, easy to upgrade and maintain;
□ Photoelectric integrated, suitable for materials and devices;
□ Wide time domain time resolution: 2.5ns-1200s;
□ Time resolution: minimum 305fs;
□ Wide wavelength range: 200-5500nm;
□ A variety of light sources, grating, detector optional;
□ Full reflection optical path design, image calibration technology;
□ SpectraHub software is configured to provide rich functions.
▌ Product function
Fluorescence/phosphorescence | Time-resolved emission spectrum | Absorption and transmission |
Electrofluorescence/phosphorescence | Fluorescent phosphor lifetime | Quantum yield |
Upconversion fluorescence | Time-resolved electroluminescence spectra | Variable temperature fluorescence |
Comparative fluorescence
| Electroluminescence response time | Low temperature fluorescence |
Time-dependent dynamics | Multidimensional spectrum | microfluorescence |
▌ Specification parameter
Spectral range |
Excitation spectrum | Standard: 200nm-900nm, optional: 200nm-2500nm |
Emission spectrum | Standard: 200nm-900nm, optional: 200nm-5500nm |
Time frame
|
SPC dynamics | 1 ms~10 h |
MCS | 10 ns~1200 s |
TCSPC | 50 ps~100 μs |
Excitation source |
Steady state | MCS | TCSPC |
350W Xenon lamp |
Pulsed xenon lamp Mic-MLD microsecond laser Mic-MLED Microsecond LED light source
|
Ina -PLD picosecond laser Ina -PLED picosecond LED light source NanoQ-NLD nanosecond laser NanoQ-NLED Nanosecond LED light source Picosecond white light source Nanosecond OPO tunable laser |
Electroluminescent components |
SMU
| Voltage range | ±15 V |
Current range | ±40 mA |
Voltage setting resolution | 10 mV |
Current setting resolution | 10 μA |
Voltage measurement resolution | 1 mV |
Current measurement resolution | 1 μA |
Transient electroluminescent driving source
| Output voltage range | -10V~+10V |
Voltage resolution | 16 bits |
Signal frequency range | 10 mHz~10 MHz |
Type of drive voltage signal | Pulse, sine wave, triangle wave, square wave, etc |
Water Raman signal-to-noise ratio
|
>12,000:1; Optimised signal to noise ratio is optional |
▌ Product application
□ Phosphor powder | □ Upconversion material | □ TADF | □ Photovoltaic material | □ Fluorescent microsphere |
| □ Organic luminescent material | □ Fluorescent probe | □ Natural dye | □ Lanthanide rare earth elements | □Carbon dot |
| □ Perovskite materials | □ AIE | □ Two-dimensional material | □ Room temperature phosphor material | □ Rare earth luminescent materials |
| □ Quantum dot | □ nanospheres | □ Quantum rod | □ Synthetic dye | □ Various kinds of electroluminescent devices |
▌ Product model
Type number | Characteristic point |
Photoluminescence and Electroluminescence Time-resolved Spectrometer(PETS) | Modular, optional configuration function; Strong upgrade and expansion function |
All-in-one machine; Steady-state and transient fluorescence functions | All-in-one machine; Steady-state and transient fluorescence functions |
Fluorescent life measuring instrument HiLight T30 | Life measurement function; Optical splitting with optional filter |
Transient electroluminescence function | Transient electroluminescence function |
Steady-state and phosphorescent functions | Steady-state and phosphorescent functions |