Electroluminescence measurement system NovaLum

Device model: NovaLum

Equipment features: Suitable for the accurate measurement of electroluminescence efficiency (current efficiency, power efficiency, external quantum efficiency, etc.), photometry, colorimetry, stability, luminescence Angle distribution and other relevant performance parameters of electroluminescence samples.

Open test: EQE, brightness, spectrum, spectral power distribution, JVL, IVL

Equipment introduction Booking instructions Sample requirement Data presentation


▌ Product introduction


The electroluminescence measurement system NovaLum is an important member of the HiOE steady-state integrated photoelectric property measurement platform of Oriental Spectra  Technology, which is used to accurately measure the performance of electroluminescence samples. The system includes IVL test, device life test, spatial Angle distribution test and other functions, which can easily and quickly obtain comprehensive performance parameters of electroluminescence devices, such as electroluminescence efficiency (current efficiency, power efficiency, external quantum efficiency, etc.), photometry, colorimetry, stability, luminescence Angle distribution and other related performance parameters. The equipment solves the problems in the industry: (1) when using the spectral radiometer test, there are low brightness test speed and high brightness over exposure, so it can not be used for the test of easily aging devices, and it is not suitable for the test of devices with a wide brightness range; (2) When using the integrating sphere system to test, it is impossible to get accurate forward brightness parameters, and there are overexposure problems at high brightness, and it is not possible to test high-luminescence samples.




▌ Test item


1. External quantum efficiency EQE;

2. Spectrum, spectral power distribution;

3. Brightness L, JVL, IVL;

4. Electrical parameters: voltage (V), current (I), current density (J), electric power (W), electric power density, etc.;

5. Radiometry: spectral power distribution, radiant flux, luminous flux, optical apparent efficiency, peak wavelength, main wavelength, etc.;

6. Colorimetry: CIE colorimetric coordinates, correlation color temperature (CCT), MK-1 (mred), color rendering index (CRI), RGB color values, etc.







1. Equipment test conditions:

(1) Spectral range: 380-780nm;


2. It is recommended to communicate with engineers in advance about relevant test requirements:

(1) Chen Gong: 13809208932 (with wechat) Southern Region (Guangdong Province, Guangxi Zhuang Autonomous Region, Jiangxi Province, Fujian Province, Hainan Province, Hubei Province, Henan Province, Hunan Province, Yunnan Province, Guizhou Province, Chongqing Municipality, Sichuan Province, Tibet Autonomous Region, Hong Kong, Macao and Taiwan)

(2) Li Gong: 13922130970 (with wechat) Northern Region (Beijing, Tianjin, Hebei, Shanxi, Shandong, Liaoning, Jilin, Heilongjiang, Inner Mongolia Autonomous Region, Shanghai, Jiangsu, Zhejiang, Anhui, Shaanxi, Ningxia Hui Autonomous Region, Gansu, Qinghai, Xinjiang Uygur Autonomous Region)



Suitable sample


1. Quantum dot light-emitting diode (QLED);

2. Organic light-emitting diode (OLED);

3. Light-emitting diode (LED);

4. Perovskite light-emitting diode (PeLED);

5. Display screen;

6. Other types of electroluminescent devices, etc.


Data presentation



No comment

Equipment introduction


▌ Product introduction


The electroluminescence measurement system NovaLum is an important member of the HiOE steady-state integrated photoelectric property measurement platform of Oriental Spectra  Technology, which is used to accurately measure the performance of electroluminescence samples. The system includes IVL test, device life test, spatial Angle distribution test and other functions, which can easily and quickly obtain comprehensive performance parameters of electroluminescence devices, such as electroluminescence efficiency (current efficiency, power efficiency, external quantum efficiency, etc.), photometry, colorimetry, stability, luminescence Angle distribution and other related performance parameters. The equipment solves the problems in the industry: (1) when using the spectral radiometer test, there are low brightness test speed and high brightness over exposure, so it can not be used for the test of easily aging devices, and it is not suitable for the test of devices with a wide brightness range; (2) When using the integrating sphere system to test, it is impossible to get accurate forward brightness parameters, and there are overexposure problems at high brightness, and it is not possible to test high-luminescence samples.




▌ Test item


1. External quantum efficiency EQE;

2. Spectrum, spectral power distribution;

3. Brightness L, JVL, IVL;

4. Electrical parameters: voltage (V), current (I), current density (J), electric power (W), electric power density, etc.;

5. Radiometry: spectral power distribution, radiant flux, luminous flux, optical apparent efficiency, peak wavelength, main wavelength, etc.;

6. Colorimetry: CIE colorimetric coordinates, correlation color temperature (CCT), MK-1 (mred), color rendering index (CRI), RGB color values, etc.






Booking instructions


1. Equipment test conditions:

(1) Spectral range: 380-780nm;


2. It is recommended to communicate with engineers in advance about relevant test requirements:

(1) Chen Gong: 13809208932 (with wechat) Southern Region (Guangdong Province, Guangxi Zhuang Autonomous Region, Jiangxi Province, Fujian Province, Hainan Province, Hubei Province, Henan Province, Hunan Province, Yunnan Province, Guizhou Province, Chongqing Municipality, Sichuan Province, Tibet Autonomous Region, Hong Kong, Macao and Taiwan)

(2) Li Gong: 13922130970 (with wechat) Northern Region (Beijing, Tianjin, Hebei, Shanxi, Shandong, Liaoning, Jilin, Heilongjiang, Inner Mongolia Autonomous Region, Shanghai, Jiangsu, Zhejiang, Anhui, Shaanxi, Ningxia Hui Autonomous Region, Gansu, Qinghai, Xinjiang Uygur Autonomous Region)


Sample requirement


Suitable sample


1. Quantum dot light-emitting diode (QLED);

2. Organic light-emitting diode (OLED);

3. Light-emitting diode (LED);

4. Perovskite light-emitting diode (PeLED);

5. Display screen;

6. Other types of electroluminescent devices, etc.


Data presentation

Data presentation



Electroluminescence measurement system NovaLum
Device model: NovaLum

Equipment features: Suitable for the accurate measurement of electroluminescence efficiency (current efficiency, power efficiency, external quantum efficiency, etc.), photometry, colorimetry, stability, luminescence Angle distribution and other relevant performance parameters of electroluminescence samples.

Open test: EQE, brightness, spectrum, spectral power distribution, JVL, IVL
Long press to look detail
Long by picture save/share
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully

Electroluminescence measurement system NovaLum

Book a test
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully
图片展示
Search

Home  |  Products  | Laboratory  |  Solution  |  Contact Us 

Call:020-66834066                 

Email:info@orientalspectra.com

Add: Unit 303, Building 5, Changxing Chuangxing Port, No. 123 Baishashui Road, Tianhe District, Guangzhou

Copyright @ Oriental Spectra All Rights Reserved ICP filing number 18054769 Oriental Spectra Technology (Guangzhou) Co., Ltd.

Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.