Fourier Transform Infrared Absorption Spectrometer INFRAVib 300

Fourier transform infrared spectroscopy is based on the Michelson interferometer, which generates an interferogram that is mathematically transformed into an infrared absorption spectrum. This technique enables the identification of molecular structures and chemical bonds. An optional attenuated total reflection (ATR) accessory allows for direct surface analysis of samples with minimal preparation.

Fourier Transform Infrared Absorption Spectrometer INFRAVib 300

Product Detail

Product Features

Fully vacuum optical design – eliminates strong absorption interference from atmospheric water vapor and CO₂

Vacuum performance – achieves vacuum degree ≤ 0.1 mbar (with vacuum pump operating) and maintains vacuum holding capacity < 1 mbar for 12 hours. The sample chamber and instrument chamber can be evacuated separately to reduce evacuation time

Automatic switching – between near-infrared, mid-infrared, and far-infrared detectors

Intelligent temperature control – equipped with intelligent temperature control technology and modules that adapt to the environment, ensuring stable performance unaffected by laboratory temperature fluctuations

Professional optical design – delivers larger light throughput and higher sensitivity

Enhanced stability – specially designed for complex environments, providing higher stability and better repeatability

ATR accessory compatibility – can be equipped with pure diamond crystal ATR accessories for measurements under vacuum conditions

Multiple external optical ports – configurable to connect various external optical cavities, such as low-temperature Dewar, high-temperature infrared emission cavity, and external sample cavity

Long-path gas cell compatibility – can be connected to a long-path gas cell for high-resolution gas spectrum measurement


Technical Specifications


Main Unitstandard configuration
Standard Configuration/Optional ConfigurationNon-Vacuum Type Main UnitConfiguration Optional
Vacuum PumpConfiguration Optional
Intelligent Temperature Control ModuleConfiguration Standard
Wavenumber Range12,500 – 50 cm⁻¹
Wavenumber Resolution≤ 0.25 cm⁻¹
IR Light SourceCeramic light source (Hg lamp and tungsten halogen lamp optional)
LaserHe-Ne laser (other lasers optional)
DetectorDLATGS / AsGaIn / MCT / Bolometer, etc. (optional)
Communication InterfaceUSB
Operating SystemWindows
Operating Temperature15 – 35°C [with Intelligent Temperature Control Module: -20°C to 80°C (non-condensing)]
SoftwareINFRAVib 300 software package included (with over 11,000 entries in IR spectral database)


No comment

Product Detail

Product Features

Fully vacuum optical design – eliminates strong absorption interference from atmospheric water vapor and CO₂

Vacuum performance – achieves vacuum degree ≤ 0.1 mbar (with vacuum pump operating) and maintains vacuum holding capacity < 1 mbar for 12 hours. The sample chamber and instrument chamber can be evacuated separately to reduce evacuation time

Automatic switching – between near-infrared, mid-infrared, and far-infrared detectors

Intelligent temperature control – equipped with intelligent temperature control technology and modules that adapt to the environment, ensuring stable performance unaffected by laboratory temperature fluctuations

Professional optical design – delivers larger light throughput and higher sensitivity

Enhanced stability – specially designed for complex environments, providing higher stability and better repeatability

ATR accessory compatibility – can be equipped with pure diamond crystal ATR accessories for measurements under vacuum conditions

Multiple external optical ports – configurable to connect various external optical cavities, such as low-temperature Dewar, high-temperature infrared emission cavity, and external sample cavity

Long-path gas cell compatibility – can be connected to a long-path gas cell for high-resolution gas spectrum measurement


Technical Specifications


Main Unitstandard configuration
Standard Configuration/Optional ConfigurationNon-Vacuum Type Main UnitConfiguration Optional
Vacuum PumpConfiguration Optional
Intelligent Temperature Control ModuleConfiguration Standard
Wavenumber Range12,500 – 50 cm⁻¹
Wavenumber Resolution≤ 0.25 cm⁻¹
IR Light SourceCeramic light source (Hg lamp and tungsten halogen lamp optional)
LaserHe-Ne laser (other lasers optional)
DetectorDLATGS / AsGaIn / MCT / Bolometer, etc. (optional)
Communication InterfaceUSB
Operating SystemWindows
Operating Temperature15 – 35°C [with Intelligent Temperature Control Module: -20°C to 80°C (non-condensing)]
SoftwareINFRAVib 300 software package included (with over 11,000 entries in IR spectral database)


Fourier Transform Infrared Absorption Spectrometer INFRAVib 300
Fourier transform infrared spectroscopy is based on the Michelson interferometer, which generates an interferogram that is mathematically transformed into an infrared absorption spectrum. This technique enables the identification of molecular structures and chemical bonds. An optional attenuated total reflection (ATR) accessory allows for direct surface analysis of samples with minimal preparation.
Long press to look detail
Long by picture save/share
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully

Fourier Transform Infrared Absorption Spectrometer INFRAVib 300

Enquiry
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully
图片展示
Search

Home  |  Products  | Laboratory  |  Solution  |  Contact Us 

Call:020-66834066                 

Email:info@orientalspectra.com

Add: Unit 303, Building 5, Changxing Chuangxing Port, No. 123 Baishashui Road, Tianhe District, Guangzhou

Copyright @ Oriental Spectra All Rights Reserved ICP filing number 18054769 Oriental Spectra Technology (Guangzhou) Co., Ltd.

Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.