Product model:HiLight HS15

Product introduction:Stable transient fluorescence spectrometer HiLight HS15, the device adopts an integrated design, including steady state, transient and other modules, operating wavelength 200 nm to 5500 nm, time range 2.5ns to 1200 s (time resolution accuracy 305fs). Suitable for all types of photoinduced (fluorescence, phosphorescence, delayed fluorescence, etc.) for comprehensive stability and transient test analysis.

Fluorescence Spectrometers HiLight HS15

Product Detail


Keywords: Stable transient fluorescence spectrum, steady state transient fluorescence spectrum, TRPL, TRES, fluorescence lifetime, fluorescence spectrum, transient fluorescence, fluorescence quantum yield, PLQY, time-resolved photoluminescence spectrum, spectrophotometer, excitation spectrum, emission spectrum, synchronization spectrum, transient phosphor, phosphor lifetime, fluorescence phosphor decay lifetime, kinetic scanning


▌ Product introduction


Stable transient fluorescence spectrometer HiLight HS15, the device adopts an integrated design, including steady state, transient and other modules, operating wavelength 200 nm to 5500 nm, time range 2.5ns to 1200 s (time resolution accuracy 305fs). Suitable for all types of photoinduced (fluorescence, phosphorescence, delayed fluorescence, etc.) for comprehensive stability, transient testing and analysis, can be widely used in materials science, analytical science, biomedicine, food science, petrochemical, geology, archaeology, forensic medicine and other fields.




▌ Product characteristics


□ Integrated design, with high stability, high sensitivity;

□ Wide time domain time resolution: 2.5ns-1200s;

□ Time resolution: minimum 305fs;

□ Wide wavelength range: 200-5500nm;

□ A variety of light sources, grating, detector optional;

□ Full reflection optical path design, image calibration technology;

□ SpectraHub software is configured to provide rich functions.





▌ Product function

Fluorescence/phosphorescence

Time-resolved emission spectrum

Absorption and transmission

Variable temperature fluorescence

Fluorescent phosphor lifetime

Quantum yield

Upconversion fluorescence

Multidimensional spectrum

Variable temperature fluorescence





▌ Technical parameter

Spectral range

Excitation spectrum

Standard: 200nm-900nm, optional: 200nm-2500nm

Emission spectrum

Standard :200nm-900nm, optional :200nm-2500nm

Time frame

SPC dynamics

1 ms~10 h

MCS

10 ns~1200 s

TCSPC

50 ps~100 μs

Excitation source

Steady state

MCS

TCSPC

350WXenon lamp

Pulsed xenon lamp

Mic-MLD microsecond laser

Mic-MLED Microsecond LED light source


Ina -PLD picosecond laser

Ina -PLED picosecond LED light source

NanoQ-NLD nanosecond laser

NanoQ-NLED Nanosecond LED light source

Picosecond white light source

Nanosecond OPO tunable laser

Water Raman signal-to-noise ratio

>12,000:1; Optimised signal to noise ratio is optional



▌ Product application

□ Phosphor powder

□ Upconversion material□ TADF□ Photovoltaic material□ Fluorescent microsphere
□ Organic luminescent material□ Fluorescent probe□ Natural dye□ Lanthanide rare earth elements□Carbon dot
□ Perovskite materials□ AIE□ Two-dimensional material□ Room temperature phosphor material□ Rare earth luminescent materials
□ Quantum dot□ nanosphere□ Quantum rod□ Synthetic dye

□ Various kinds of electroluminescent devices






No comment

Product Detail


Keywords: Stable transient fluorescence spectrum, steady state transient fluorescence spectrum, TRPL, TRES, fluorescence lifetime, fluorescence spectrum, transient fluorescence, fluorescence quantum yield, PLQY, time-resolved photoluminescence spectrum, spectrophotometer, excitation spectrum, emission spectrum, synchronization spectrum, transient phosphor, phosphor lifetime, fluorescence phosphor decay lifetime, kinetic scanning


▌ Product introduction


Stable transient fluorescence spectrometer HiLight HS15, the device adopts an integrated design, including steady state, transient and other modules, operating wavelength 200 nm to 5500 nm, time range 2.5ns to 1200 s (time resolution accuracy 305fs). Suitable for all types of photoinduced (fluorescence, phosphorescence, delayed fluorescence, etc.) for comprehensive stability, transient testing and analysis, can be widely used in materials science, analytical science, biomedicine, food science, petrochemical, geology, archaeology, forensic medicine and other fields.




▌ Product characteristics


□ Integrated design, with high stability, high sensitivity;

□ Wide time domain time resolution: 2.5ns-1200s;

□ Time resolution: minimum 305fs;

□ Wide wavelength range: 200-5500nm;

□ A variety of light sources, grating, detector optional;

□ Full reflection optical path design, image calibration technology;

□ SpectraHub software is configured to provide rich functions.





▌ Product function

Fluorescence/phosphorescence

Time-resolved emission spectrum

Absorption and transmission

Variable temperature fluorescence

Fluorescent phosphor lifetime

Quantum yield

Upconversion fluorescence

Multidimensional spectrum

Variable temperature fluorescence





▌ Technical parameter

Spectral range

Excitation spectrum

Standard: 200nm-900nm, optional: 200nm-2500nm

Emission spectrum

Standard :200nm-900nm, optional :200nm-2500nm

Time frame

SPC dynamics

1 ms~10 h

MCS

10 ns~1200 s

TCSPC

50 ps~100 μs

Excitation source

Steady state

MCS

TCSPC

350WXenon lamp

Pulsed xenon lamp

Mic-MLD microsecond laser

Mic-MLED Microsecond LED light source


Ina -PLD picosecond laser

Ina -PLED picosecond LED light source

NanoQ-NLD nanosecond laser

NanoQ-NLED Nanosecond LED light source

Picosecond white light source

Nanosecond OPO tunable laser

Water Raman signal-to-noise ratio

>12,000:1; Optimised signal to noise ratio is optional



▌ Product application

□ Phosphor powder

□ Upconversion material□ TADF□ Photovoltaic material□ Fluorescent microsphere
□ Organic luminescent material□ Fluorescent probe□ Natural dye□ Lanthanide rare earth elements□Carbon dot
□ Perovskite materials□ AIE□ Two-dimensional material□ Room temperature phosphor material□ Rare earth luminescent materials
□ Quantum dot□ nanosphere□ Quantum rod□ Synthetic dye

□ Various kinds of electroluminescent devices






Fluorescence Spectrometers HiLight HS15
Product model:HiLight HS15

Product introduction:Stable transient fluorescence spectrometer HiLight HS15, the device adopts an integrated design, including steady state, transient and other modules, operating wavelength 200 nm to 5500 nm, time range 2.5ns to 1200 s (time resolution accuracy 305fs). Suitable for all types of photoinduced (fluorescence, phosphorescence, delayed fluorescence, etc.) for comprehensive stability and transient test analysis.
Long press to look detail
Long by picture save/share
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully

Fluorescence Spectrometers HiLight HS15

Enquiry
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully
图片展示
Search

Home  |  Products  | Laboratory  |  Solution  |  Contact Us 

Call:020-66834066                 

Email:info@orientalspectra.com

Add: Unit 303, Building 5, Changxing Chuangxing Port, No. 123 Baishashui Road, Tianhe District, Guangzhou

Copyright @ Oriental Spectra All Rights Reserved ICP filing number 18054769 Oriental Spectra Technology (Guangzhou) Co., Ltd.

Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.